Brazilian Journal of Pulmonology

ISSN (on-line): 1806-3756 | ISSN (printed): 1806-3713

SBPT

Publication continuous and bimonthly

SCImago Journal & Country Rank
Advanced Search

Search Results

The search for the author or contributors found : 1 results


The rapid shallow breathing index as a predictor of successful mechanical ventilation weaning: clinical utility when calculated from ventilator data

Índice de respiração rápida e superficial como previsor de sucesso de desmame da ventilação mecânica: utilidade clínica quando mensurado a partir de dados do ventilador

Leonardo Cordeiro de Souza1,2,3,4, Jocemir Ronaldo Lugon1,5

J Bras Pneumol.2015;41(6):530-535

Abstract PDF PT PDF EN Portuguese Text

Objective: The use of the rapid shallow breathing index (RSBI) is recommended in ICUs, where it is used as a predictor of mechanical ventilation (MV) weaning success. The aim of this study was to compare the performance of the RSBI calculated by the traditional method (described in 1991) with that of the RSBI calculated directly from MV parameters. Methods: This was a prospective observational study involving patients who had been on MV for more than 24 h and were candidates for weaning. The RSBI was obtained by the same examiner using the two different methods (employing a spirometer and the parameters from the ventilator display) at random. In comparing the values obtained with the two methods, we used the Mann-Whitney test, Pearson's linear correlation test, and Bland-Altman plots. The performance of the methods was compared by evaluation of the areas under the ROC curves. Results: Of the 109 selected patients (60 males; mean age, 62 ± 20 years), 65 were successfully weaned, and 36 died. There were statistically significant differences between the two methods for respiratory rate, tidal volume, and RSBI (p < 0.001 for all). However, when the two methods were compared, the concordance and the intra-observer variation coefficient were 0.94 (0.92-0.96) and 11.16%, respectively. The area under the ROC curve was similar for both methods (0.81 ± 0.04 vs. 0.82 ± 0.04; p = 0.935), which is relevant in the context of this study. Conclusions: The satisfactory performance of the RSBI as a predictor of weaning success, regardless of the method employed, demonstrates the utility of the method using the mechanical ventilator.

 


Keywords: Respiration, artificial; Ventilator weaning; Spirometry.

 


 

 


The Brazilian Journal of Pulmonology is indexed in:

Latindex Lilacs SciELO PubMed ISI Scopus Copernicus pmc

Support

CNPq, Capes, Ministério da Educação, Ministério da Ciência e Tecnologia, Governo Federal, Brasil, País Rico é País sem Pobreza
Secretariat of the Brazilian Journal of Pulmonology
SCS Quadra 01, Bloco K, Salas 203/204 Ed. Denasa. CEP: 70.398-900 - Brasília - DF
Fone/fax: 0800 61 6218/ (55) (61) 3245 1030/ (55) (61) 3245 6218
E-mails: jbp@jbp.org.br
jpneumo@jornaldepneumologia.com.br

Copyright 2019 - Brazilian Thoracic Association

Logo GN1