Continuous and bimonthly publication
ISSN (on-line): 1806-3756

Licença Creative Commons
23720
Views
Back to summary
Open Access Peer-Reviewed
Artigo de Revisão

Diaphragmatic ultrasound: a review of its methodological aspects and clinical uses

Ultrassonografia diafragmática: uma revisão de seus aspectos metodológicos e usos clínicos

Pauliane Vieira Santana1,2, Leticia Zumpano Cardenas1,2, André Luis Pereira de Albuquerque1,3, Carlos Roberto Ribeiro de Carvalho1, Pedro Caruso1,2

Supplementary Material

SUPPLEMENTARY MATERIAL
MATERIAL SUPLEMENTAR)
A BRIEF REVIEW OF METHODS OTHER THAN ULTRASOUND USED IN ORDER TO EVALUATE THE DIAPHRAGM Fluoroscopy Although fluoroscopy is widely available, simple to perform, and easy to interpret, it has proven to be inaccurate in some situations.(1) Investigators have reported false-positive results of fluoroscopy during the sniff maneuver test in approximately 6% of patients with bilateral diaphragmatic dysfunction (DD).(1) False-negative results can also occur when, at the onset of inspiration, abrupt diaphragmatic caudal motion occurs due to the active contraction of the abdominal muscles during the previous expiration (that brought lung volume down to the functional residual capacity), followed by abrupt relaxation of the abdominal muscles.(1) In addition, fluoroscopy has certain limitations(2): it requires patients to breathe spontaneously, it involves significant radiation exposure, and it requires transportation of the patient to the fluoroscopy unit. Pulmonary function testing Pulmonary function testing (PFT) may be helpful to diagnose DD because it is inexpensive, largely available, and noninvasive, as well as having well-known reference values. A 10-30% decrease in the lung vital capacity from the upright to the supine position is suggestive of unilateral DD, whereas a reduction greater than 30% is suggestive of bilateral DD.(3) One important limitation of PFT is that some individuals are intolerant of the supine position. Other limitations are the wide range of normal values, the volitional nature (dependence on patient effort), and the low sensitivity to detect early involvement of the respiratory muscles.(2) Evaluation of global respiratory muscle strength Tests to determine MIP, sniff nasal inspiratory pressure (SNIP), and MEP are simple, noninvasive, and widely used methods of investigating global respiratory muscle strength. In patients with unilateral diaphragmatic paralysis, MIP and SNIP are usually reduced to approximately 60% of the predicted value, whereas in bilateral diaphragmatic paralysis, a more marked reduction (to less than 30% of the predicted value) may be observed. The MEP is generally preserved if muscle dysfunction spares the abdominal expiratory muscles. Concomitant reductions in MIP (or SNIP) and MEP suggest generalized muscle dysfunction. Limitations include the volitional nature and variability of the tests.(4) Measurement of transdiaphragmatic pressure Measurement of transdiaphragmatic pressure (Pdi) is considered the gold standard for the diagnosis of bilateral diaphragmatic dysfunction.(4) During a sniff maneuver or a maximal inspiratory effort, a Pdi value ≥ 80 cmH2O in men and ≥ 70 cmH2O in women rules out clinically significant diaphragmatic weakness.(4) In patients unable to perform the maneuvers, magnetic stimulation of the phrenic nerve is a helpful surrogate.(4) The Pdi measurement is limited because it is invasive, uncomfortable, and time-consuming; because it requires technical skills and expensive equipment to yield reliable results; and because it is usually restricted to research laboratories.(4) CT Although chest CT can assess the diaphragm thickness and the height of the lungs, it has several limitations: the diaphragm measurement is not standardized(5); the exposure of patients to radiation; the requirement for the supine position, which many patients with DD cannot tolerate; the high cost; the static measurement without assessment of muscular motion; and the fact that the hemidiaphragms are thin and isodense in relation to the liver and spleen, making them indistinguishable from the adjacent organs. Magnetic resonance imaging Magnetic resonance imaging has rarely been employed for the evaluation of diaphragmatic function, because it has some of the same limitations as CT (no standardization; the requirement for the supine position; high cost, and static measurement).(6) REFERENCES 1. Alexander C. Diaphragm movements and the diagnosis of diaphragmatic paralysis. Clin Radiol. 1966;17(1):79-83. https://doi.org/10.1016/S0009-9260(66)80128-9 2. McCool FD, Tzelepis GE. Dysfunction of the diaphragm [published correction appears in N Engl J Med. 2012 May 31;366(22):2138]. N Engl J Med. 2012;366(10):932-942. https://doi.org/10.1056/NEJMra1007236 3. Laroche CM, Carroll N, Moxham J, Green M. Clinical significance of severe isolated diaphragm weakness. Am Rev Respir Dis. 1988;138(4):862-866. https://doi.org/10.1164/ajrccm/138.4.862 4. American Thoracic Society/European Respiratory Society. ATS/ERS Statement on respiratory muscle testing. Am J Respir Crit Care Med. 2002;166(4):518-624. https://doi.org/10.1164/rccm.166.4.518 5. Caskey CI, Zerhouni EA, Fishman EK, Rahmouni AD. Aging of the diaphragm: a CT study. Radiology. 1989;171(2):385-389. https://doi.org/10.1148/radiology.171.2.2704802 6. Nason LK, Walker CM, McNeeley MF, Burivong W, Fligner CL, Godwin JD. Imaging of the diaphragm: anatomy and function. Radiographics. 2012;32(2):E51-E70. https://doi.org/10.1148/rg.322115127

Indexes

Development by:

© All rights reserved 2024 - Jornal Brasileiro de Pneumologia